Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 15 de 15
Filter
1.
Biosensors (Basel) ; 12(9)2022 Sep 19.
Article in English | MEDLINE | ID: covidwho-2258345

ABSTRACT

Molecularly imprinted polymers (MIPs) are widely used as modifiers in electrochemical sensors due to their high sensitivity and promise of inexpensive mass manufacturing. Here, we propose and demonstrate a novel MIP-sensor that can measure the electrochemical activity of favipiravir (FAV) as an antiviral drug, thereby enabling quantification of the concentration of FAV in biological and river water samples and in real-time. MOF nanoparticles' application with various shapes to determine FAV at nanomolar concentrations was described. Two different MOF nanoparticle shapes (dodecahedron and sheets) were systematically compared to evaluate the electrochemical performance of FAV. After carefully examining two different morphologies of MIP-Co-Ni@MOF, the nanosheet form showed a higher performance and efficiency than the nanododecahedron. When MIP-Co/Ni@MOF-based and NIP-Co/Ni@MOF electrodes (nanosheets) were used instead, the minimum target concentrations detected were 7.5 × 10-11 (MIP-Co-Ni@MOF) and 8.17 × 10-9 M (NIP-Co-Ni@MOF), respectively. This is a significant improvement (>102), which is assigned to the large active surface area and high fraction of surface atoms, increasing the amount of greater analyte adsorption during binding. Therefore, water-dispersible MIP-Co-Ni@MOF nanosheets were successfully applied for trace-level determination of FAV in biological and water samples. Our findings seem to provide useful guidance in the molecularly imprinted polymer design of MOF-based materials to help establish quantitative rules in designing MOF-based sensors for point of care (POC) systems.


Subject(s)
Molecular Imprinting , Amides , Antiviral Agents , Electrochemical Techniques , Electrodes , Metals , Molecularly Imprinted Polymers , Polymers , Pyrazines , Water
2.
Talanta ; 253: 123907, 2023 Feb 01.
Article in English | MEDLINE | ID: covidwho-2008140

ABSTRACT

A cost-effective, highly selective and sensitive paper-based potentiometric combined sensor for losartan potassium drug (LOS) is fabricated, characterized and used for the drug monitoring. The sensor consists of 2 strips of filter paper (20 × 5 mm each) as platform, each imprinted with 4 mm diameter circular spot of carbon. One carbon spot is covered by a reduced graphene oxide (rGO) for use as a substrate for the recognition sensor and the other without rGO is used for the reference electrode. LOS molecularly imprinted drug polymer (MIP) is applied onto the graphene oxide containing strip to act as a drug recognition sensing material and a solid-state polyvinyl butyral (PVB) is applied onto the second carbon spot to act as a reference electrode. Performance characteristics of the combined sensor are examined with chronopotentiometry (CP) and electrochemical impedance spectroscopy (EIS). Increase effect of rGO on the interfacial double-layer capacitance of the sensing membrane and consequently on the potential stability is confirmed. The developed combined sensor (strip cell) displays a Nernstian slope of -58.2 ± 0.3 mV/decade (R2 = 0.9994) over the linear range 8.5 × 10-7 - 6.9 × 10-2 M with a detection limit of 2.7 ± 0.3 × 10-7 M. The sensor shows remarkable selectivity toward various related compounds especially those commonly used by the COVID-19 patients such as paracetamol, ascorbic acid and dextromethorphan. The assay method is validated and proved to be satisfactory for direct potentiometric determination of LOS-K in some pharmaceutical formulations and in spiked human urine samples. An average recovery of 96.3 ± 0.3-98.7 ± 0.6% of the nominal or spiked concentration and a mean relative standard deviation of ±0.6% are obtained. The use of an indicating and a reference electrodes combined into a single flexible disposable paper platform enables applications to a minimum sample volume due to the close proximity of the responsive membrane and the liquid junction. The efficiency of the proposed sensor in complex urine matrix suggests its application in hospitals for rapid diagnosis of overdose patients and for quality control/quality assurance tests in pharmaceutical industry.


Subject(s)
COVID-19 , Molecularly Imprinted Polymers , Humans , Losartan , Carbon
3.
Molecules ; 27(10)2022 May 21.
Article in English | MEDLINE | ID: covidwho-1875717

ABSTRACT

A novel molecularly imprinted polymer (MIP) has been developed based on a simple and sustainable strategy for the selective determination of citalopram (CTL) using screen-printed carbon electrodes (SPCEs). The MIP layer was prepared by electrochemical in situ polymerization of the 3-amino-4 hydroxybenzoic acid (AHBA) functional monomer and CTL as a template molecule. To simulate the polymerization mixture and predict the most suitable ratio between the template and functional monomer, computational studies, namely molecular dynamics (MD) simulations, were carried out. During the experimental preparation process, essential parameters controlling the performance of the MIP sensor, including CTL:AHBA concentration, number of polymerization cycles, and square wave voltammetry (SWV) frequency were investigated and optimized. The electrochemical characteristics of the prepared MIP sensor were evaluated by both cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) techniques. Based on the optimal conditions, a linear electrochemical response of the sensor was obtained by SWV measurements from 0.1 to 1.25 µmol L-1 with a limit of detection (LOD) of 0.162 µmol L-1 (S/N = 3). Moreover, the MIP sensor revealed excellent CTL selectivity against very close analogues, as well as high imprinting factor of 22. Its applicability in spiked river water samples demonstrated its potential for adequate monitoring of CTL. This sensor offers a facile strategy to achieve portability while expressing a willingness to care for the environment.


Subject(s)
Molecular Imprinting , Molecularly Imprinted Polymers , Citalopram , Computer Simulation , Electrochemical Techniques/methods , Molecular Imprinting/methods
4.
ACS Sens ; 7(4): 1122-1131, 2022 04 22.
Article in English | MEDLINE | ID: covidwho-1788266

ABSTRACT

Rapid antigen tests are currently used for population screening of COVID-19. However, they lack sensitivity and utilize antibodies as receptors, which can only function in narrow temperature and pH ranges. Consequently, molecularly imprinted polymer nanoparticles (nanoMIPs) are synthetized with a fast (2 h) and scalable process using merely a tiny SARS-CoV-2 fragment (∼10 amino acids). The nanoMIPs rival the affinity of SARS-CoV-2 antibodies under standard testing conditions and surpass them at elevated temperatures or in acidic media. Therefore, nanoMIP sensors possess clear advantages over antibody-based assays as they can function in various challenging media. A thermal assay is developed with nanoMIPs electrografted onto screen-printed electrodes to accurately quantify SARS-CoV-2 antigens. Heat transfer-based measurements demonstrate superior detection limits compared to commercial rapid antigen tests and most antigen tests from the literature for both the alpha (∼9.9 fg mL-1) and delta (∼6.1 fg mL-1) variants of the spike protein. A prototype assay is developed, which can rapidly (∼15 min) validate clinical patient samples with excellent sensitivity and specificity. The straightforward epitope imprinting method and high robustness of nanoMIPs produce a SARS-CoV-2 sensor with significant commercial potential for population screening, in addition to the possibility of measurements in diagnostically challenging environments.


Subject(s)
COVID-19 , Molecular Imprinting , Nanoparticles , Antibodies , COVID-19/diagnosis , Humans , Molecularly Imprinted Polymers , Nanoparticles/chemistry , Point-of-Care Systems , SARS-CoV-2
5.
Anal Chim Acta ; 1206: 339777, 2022 May 08.
Article in English | MEDLINE | ID: covidwho-1767809

ABSTRACT

We investigate electropolymerized molecularly imprinted polymers (E-MIPs) for the selective recognition of SARS-CoV-2 whole virus. E-MIPs imprinted with SARS-CoV-2 pseudoparticles (pps) were electrochemically deposited onto screen printed electrodes by reductive electropolymerization, using the water-soluble N-hydroxmethylacrylamide (NHMA) as functional monomer and crosslinked with N,N'-methylenebisacrylamide (MBAm). E-MIPs for SARS-CoV-2 showed selectivity for template SARS-CoV-2 pps, with an imprinting factor of 3:1, and specificity (significance = 0.06) when cross-reacted with other respiratory viruses. E-MIPs detected the presence of SARS-CoV-2 pps in <10 min with a limit of detection of 4.9 log10 pfu/mL, suggesting their suitability for detection of SARS-CoV-2 with minimal sample preparation. Using electrochemical impedance spectroscopy (EIS) and principal component analysis (PCA), the capture of SARS-CoV-2 from real patient saliva samples was also evaluated. Fifteen confirmed COVID-19 positive and nine COVID-19 negative saliva samples were compared against the established loop-mediated isothermal nucleic acid amplification (LAMP) technique used by the UK National Health Service. EIS data demonstrated a PCA discrimination between positive and negative LAMP samples. A threshold real impedance signal (ZRe) ≫ 4000 Ω and a corresponding charge transfer resistance (RCT) ≫ 6000 Ω was indicative of absence of virus (COVID-19 negative) in agreement with values obtained for our control non-imprinted polymer control. A ZRe at or below a threshold value of 600 Ω with a corresponding RCT of <1200 Ω was indicative of a COVID-19 positive sample. The presence of virus was confirmed by treatment of E-MIPs with a SARS-CoV-2 specific monoclonal antibody.


Subject(s)
COVID-19 , Molecularly Imprinted Polymers , Antibodies, Viral , COVID-19/diagnosis , Electrodes , Humans , SARS-CoV-2 , Saliva , State Medicine
6.
Biosensors (Basel) ; 12(3)2022 Feb 22.
Article in English | MEDLINE | ID: covidwho-1760366

ABSTRACT

Recent developments of point-of-care testing (POCT) and in vitro diagnostic medical devices have provided analytical capabilities and reliable diagnostic results for rapid access at or near the patient's location. Nevertheless, the challenges of reliable diagnosis still remain an important factor in actual clinical trials before on-site medical treatment and making clinical decisions. New classes of POCT devices depict precise diagnostic technologies that can detect biomarkers in biofluids such as sweat, tears, saliva or urine. The introduction of a novel molecularly imprinted polymer (MIP) system as an artificial bioreceptor for the POCT devices could be one of the emerging candidates to improve the analytical performance along with physicochemical stability when used in harsh environments. Here, we review the potential availability of MIP-based biorecognition systems as custom artificial receptors with high selectivity and chemical affinity for specific molecules. Further developments to the progress of advanced MIP technology for biomolecule recognition are introduced. Finally, to improve the POCT-based diagnostic system, we summarized the perspectives for high expandability to MIP-based periodontal diagnosis and the future directions of MIP-based biosensors as a wearable format.


Subject(s)
Biosensing Techniques , Molecular Imprinting , Biosensing Techniques/methods , Humans , Molecularly Imprinted Polymers , Point-of-Care Systems , Point-of-Care Testing , Sweat
7.
Mikrochim Acta ; 189(3): 125, 2022 03 01.
Article in English | MEDLINE | ID: covidwho-1712245

ABSTRACT

A novel electrochemical sensor is reported for the detection of the antiviral drug favipiravir based on the core-shell nanocomposite of flower-like molybdenum disulfide (MoS2) nanospheres and molecularly imprinted polymers (MIPs). The MoS2@MIP core-shell nanocomposite was prepared via the electrodeposition of a MIP layer on the MoS2 modified electrode, using o-phenylenediamine as the monomer and favipiravir as the template. The selective binding of target favipiravir at the MoS2@MIP core-shell nanocomposite produced a redox signal in a concentration dependent manner, which was used for the quantitative analysis. The preparation process of the MoS2@MIP core-shell nanocomposite was optimized. Under the optimal conditions, the sensor exhibited a wide linear response range of 0.01 ~ 100 nM (1.57*10-6 ~ 1.57*10-2 µg mL-1) and a low detection limit of 0.002 nM (3.14*10-7 µg mL-1). Application of the sensor was demonstrated by detecting favipiravir in a minimum amount of 10 µL biological samples (urine and plasma). Satisfied results in the recovery tests indicated a high potential of favipiravir monitoring in infectious COVID-19 samples.


Subject(s)
Amides/analysis , Antiviral Agents/analysis , Disulfides/chemistry , Molecularly Imprinted Polymers/chemistry , Molybdenum/chemistry , Nanocomposites/chemistry , Nanospheres/chemistry , Pyrazines/analysis , Amides/blood , Amides/therapeutic use , Amides/urine , Antiviral Agents/blood , Antiviral Agents/therapeutic use , Antiviral Agents/urine , COVID-19/virology , Electrochemical Techniques/methods , Humans , Limit of Detection , Oxidation-Reduction , Pyrazines/blood , Pyrazines/therapeutic use , Pyrazines/urine , Reproducibility of Results , SARS-CoV-2/isolation & purification , COVID-19 Drug Treatment
8.
Int J Mol Sci ; 23(3)2022 Jan 22.
Article in English | MEDLINE | ID: covidwho-1686809

ABSTRACT

Recently, the studies on developing sensors and biosensors-with an obvious interdisciplinary character-have drawn the attention of many researchers specializing in various fundamental, but also complex domains such as chemistry, biochemistry, physics, biophysics, biology, bio-pharma-medicine, and bioengineering. Along these lines, the present paper is structured into three parts, and is aimed at synthesizing the most relevant studies on the construction and functioning of versatile devices, of electrochemical sensors and biosensors, respectively. The first part presents examples of the most representative scientific research focusing on the role and the importance of the phenylalanine, tyrosine, and tryptophan amino acids, selected depending on their chemical structure and their impact on the central nervous system. The second part is dedicated to presenting and exemplifying conductor polymers and molecularly imprinted polymers used as sensitive materials in achieving electrochemical sensors and biosensors. The last part of the review analyzes the sensors and biosensors developed so far to detect amino acids with the aid of conductor polymers and molecularly imprinted polymers from the point of view of the performances obtained, with emphasis on the detection methods, on the electrochemical reactions that take place upon detection, and on the electroanalytical performances. The present study was carried out with a view to highlighting, for the benefit of specialists in medicine and pharmacy, the possibility of achieving and purchasing efficient devices that might be used in the quality control of medicines, as well as in studying and monitoring diseases associated with these amino acids.


Subject(s)
Biosensing Techniques/instrumentation , Electrochemical Techniques/methods , Molecular Imprinting/methods , Molecularly Imprinted Polymers/chemistry , Phenylalanine/analysis , Tryptophan/analysis , Tyrosine/analysis , Amino Acids/analysis , Polymers/chemistry
9.
Biosensors (Basel) ; 12(1)2022 Jan 15.
Article in English | MEDLINE | ID: covidwho-1640558

ABSTRACT

Rapid, selective, and cost-effective detection and determination of clinically relevant biomolecule analytes for a better understanding of biological and physiological functions are becoming increasingly prominent. In this regard, biosensors represent a powerful tool to meet these requirements. Recent decades have seen biosensors gaining popularity due to their ability to design sensor platforms that are selective to determine target analytes. Naturally generated receptor units have a high affinity for their targets, which provides the selectivity of a device. However, such receptors are subject to instability under harsh environmental conditions and have consequently low durability. By applying principles of supramolecular chemistry, molecularly imprinted polymers (MIPs) can successfully replace natural receptors to circumvent these shortcomings. This review summarizes the recent achievements and analytical applications of electrosynthesized MIPs, in particular, for the detection of protein-based biomarkers. The scope of this review also includes the background behind electrochemical readouts and the origin of the gate effect in MIP-based biosensors.


Subject(s)
Biosensing Techniques , Molecular Imprinting , Biomimetics , Biosensing Techniques/instrumentation , Equipment Design , Molecular Imprinting/methods , Molecularly Imprinted Polymers , Polymers/chemistry , Proteins
10.
Biosensors (Basel) ; 12(1)2022 Jan 07.
Article in English | MEDLINE | ID: covidwho-1613612

ABSTRACT

C-reactive protein (CRP) is a non-specific biomarker of inflammation and may be associated with cardiovascular disease. In recent studies, systemic inflammatory responses have also been observed in cases of coronavirus disease 2019 (COVID-19). Molecularly imprinted polymers (MIPs) have been developed to replace natural antibodies with polymeric materials that have low cost and high stability and could thus be suitable for use in a home-care system. In this work, a MIP-based electrochemical sensing system for measuring CRP was developed. Such a system can be integrated with microfluidics and electronics for lab-on-a-chip technology. MIP composition was optimized using various imprinting template (CRP peptide) concentrations. Tungsten disulfide (WS2) was doped into the MIPs. Doping not only enhances the electrochemical response accompanying the recognition of the template molecules but also raises the top of the sensing range from 1.0 pg/mL to 1.0 ng/mL of the imprinted peptide. The calibration curve of the WS2-doped peptide-imprinted polymer-coated electrodes in the extended-gate field-effect transistor platform was obtained and used for the measurement of CRP concentration in real human serum.


Subject(s)
C-Reactive Protein/analysis , Molecularly Imprinted Polymers , Sulfides , Tungsten Compounds , Electrochemical Techniques , Electrodes , Humans , Peptides
11.
Biosens Bioelectron ; 196: 113729, 2022 Jan 15.
Article in English | MEDLINE | ID: covidwho-1482463

ABSTRACT

Herein, a novel molecularly imprinted polymer (MIP) based electrochemical sensor for the determination of the receptor-binding domain of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2-RBD) has been developed. For this purpose, first, a macroporous gold screen-printed electrode (MP-Au-SPE) has been fabricated. The MIP was then synthesized on the surface of the MP-Au-SPE through the electro-polymerization of ortho-phenylenediamine in the presence of SARS-CoV-2-RBD molecules as matrix polymer, and template molecules, respectively. During the fabrication process, the SARS-CoV-2-RBD molecules were embedded in the polymer matrix. Subsequently, the template molecules were removed from the electrode by using alkaline ethanol. The template molecules removal was studied using cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), scanning electron microscope (SEM), energy-dispersive X-ray spectroscopy (EDX), and attenuated total reflectance spectroscopy (ATR). The fabricated MIP film acted as an artificial recognition element for the measurement of SARS-CoV-2-RBD. The EIS technique was used for the measurement of the SARS-CoV-2-RBD in the saliva solution. The electron transfer resistance (Ret) of the MIP-based sensor in a ferri/ferrocyanide solution increased as the SARS-CoV-2-RBD concentration increased due to the occupation of the imprinted cavities by the SARS-CoV-2-RBD. The MIP-based sensor exhibited a good response to the SARS-CoV-2-RBD in the concentration range between 2.0 and 40.0 pg mL-1 with a limit of detection of 0.7 pg mL-1. The obtained results showed that the fabricated MIP sensor has high selectivity sensitivity, and stability.


Subject(s)
Biosensing Techniques , COVID-19 , Molecular Imprinting , Electrochemical Techniques , Electrodes , Gold , Humans , Limit of Detection , Molecularly Imprinted Polymers , SARS-CoV-2
12.
J Nanobiotechnology ; 19(1): 305, 2021 Oct 06.
Article in English | MEDLINE | ID: covidwho-1455975

ABSTRACT

Molecular imprinting (MI) is a technique that creates a template of a molecule for improving complementary binding sites in terms of size and shape to a peptide, protein, bacteria, mammalian cell, or virus on soft materials (such as polymers, hydrogels, or self-assembled materials). MI has been widely investigated for over 90 years in various industries but is now focused on improved tissue engineering, regenerative medicine, drug delivery, sensors, diagnostics, therapeutics and other medical applications. Molecular targets that have been studied so far in MI include those for the major antigenic determinants of microorganisms (like bacteria or viruses) leading to innovations in disease diagnosis via solid-phase extraction separation and biomimetic sensors. As such, although not widely investigated yet, MI demonstrates much promise for improving the detection of and treatment for the current Coronavirus Disease of 2019 (COVID-2019) pandemic as well as future pandemics. In this manner, this review will introduce the numerous applications of MI polymers, particularly using proteins and peptides, and how these MI polymers can be used as improved diagnostic and therapeutic tools for COVID-19.


Subject(s)
COVID-19/diagnosis , Molecularly Imprinted Polymers/therapeutic use , SARS-CoV-2/isolation & purification , Antibodies , Drug Carriers , Humans , Molecular Imprinting , Molecularly Imprinted Polymers/chemistry , Peptides , Proteins , Receptors, Cell Surface
13.
Nanoscale ; 13(40): 16885-16899, 2021 Oct 21.
Article in English | MEDLINE | ID: covidwho-1413378

ABSTRACT

The present research study reports the development of plastic antibodies based on Molecularly Imprinted Polymers (MIPs) capable of selectively binding a portion of the novel coronavirus SARS-CoV-2 spike protein. Indeed, molecular imprinting represents a very promising and attractive technology for the synthesis of MIPs characterized by specific recognition abilities for a target molecule. Given these characteristics, MIPs can be considered tailor-made synthetic antibodies obtained by a templating process. After in silico analysis, imprinted nanoparticles were synthesized by inverse microemulsion polymerization and their ability to prevent the interaction between ACE2 and the receptor-binding domain of SARS-CoV-2 was investigated. Of relevance, the developed synthetic antibodies are capable of significantly inhibiting virus replication in Vero cell culture, suggesting their potential application in the treatment, prevention and diagnosis of SARS-CoV-2 infection.


Subject(s)
COVID-19 , Molecularly Imprinted Polymers , Humans , Plastics , Protein Binding , SARS-CoV-2 , Spike Glycoprotein, Coronavirus
14.
Biotechnol Prog ; 37(2): e3112, 2021 03.
Article in English | MEDLINE | ID: covidwho-1384129

ABSTRACT

Angiotensin II (AngII), the effector peptide of the renin angiotensin system and has an important role in regulating cardiovascular hemodynamics and structure. AngII is an important biomarker for certain diseases that are associated with cardiovascular disorders, i.e., influenza, SARS-CoV-2, tumors, hypertension, etc. However, AngII presents in blood in very low concentrations and they are not stable due to their reactivity, therefore spontaneous detection of AngII is a big challenge. In this study, AngII-imprinted spongy columns (AngII-misc) synthesized for AngII detection from human serum, and characterized by surface area measurements (BET), swelling tests, scanning electron microscopy (SEM), FTIR studies. AngII binding studies were achieved from aqueous environment and maximum binding capacity was found as 0.667 mg/g. It was calculated that the AngII-miscs recognized AngII 8.27 and 14.25 times more selectively than competitor Angiotensin I and Vasopressin molecules. Newly produced AngII-misc binds 60.5 pg/g AngII from crude human serum selectively. It has a great potential for spontaneous detection of AngII from human serum for direct and critical measurements in serious diseases, that is, heart attacks, SARS-CoV-2, etc.


Subject(s)
Angiotensin II/blood , Molecularly Imprinted Polymers , Angiotensin II/isolation & purification , Biomarkers/blood , Humans , Protein Binding
15.
Sensors (Basel) ; 21(5)2021 Mar 01.
Article in English | MEDLINE | ID: covidwho-1125776

ABSTRACT

The rapid spread of the Coronavirus Disease 2019 (COVID-19) pandemic, caused by the Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) pathogen has generated a huge international public health emergency. Currently the reference diagnostic technique for virus determination is Reverse Transcription Polymerase Chain Reaction (RT-PCR) real time analysis that requires specialized equipment, reagents and facilities and typically 3-4 h to perform. Thus, the realization of simple, low-cost, small-size, rapid and point-of-care diagnostics tests has become a global priority. In response to the current need for quick, highly sensitive and on-site detection of the SARS-CoV-2 virus in several aqueous solutions, a specific molecularly imprinted polymer (MIP) receptor has been designed, realized, and combined with an optical sensor. More specifically, the proof of concept of a SARS-CoV-2 sensor has been demonstrated by exploiting a plasmonic plastic optical fiber sensor coupled with a novel kind of synthetic MIP nano-layer, especially designed for the specific recognition of Subunit 1 of the SARS-CoV-2 Spike protein. First, we have tested the effectiveness of the developed MIP receptor to bind the Subunit 1 of the SARS-CoV-2 spike protein, then the results of preliminary tests on SARS-CoV-2 virions, performed on samples of nasopharyngeal (NP) swabs in universal transport medium (UTM) and physiological solution (0.9% NaCl), were compared with those obtained with RT-PCR. According to these preliminary results, the sensitivity of the proposed optical-chemical sensor proved to be higher than the RT-PCR one. Furthermore, a relatively fast response time (about 10 min) to the virus was obtained without the use of additional reagents.


Subject(s)
COVID-19/diagnosis , Molecularly Imprinted Polymers , Optical Fibers , SARS-CoV-2/isolation & purification , Humans , Sensitivity and Specificity , Spike Glycoprotein, Coronavirus
SELECTION OF CITATIONS
SEARCH DETAIL